Steam Generator Test Facility
|
I.B.Noushad,
Plant Superintendent, SGTF |
I.B.Noushad,
Head, SGTF (M) |
|
V.A.Sureshkumar,
Head, SGTF (O) |
|
SECTION |
ACTIVITIES |
|
SGTF Maintenance
Section (SGTF
(M))
|
-
Maintenance of Steam
Generator Test Facility (SGTF)
|
|
SGTF Operation
Section (SGTF
OS) |
-
Operation of Steam
Generator Test Facility (SGTF)
-
Optimize the design of
Steam Generator (SG) for FBRs
-
Assessment of SG heat
transfer area and waterside pressure drop safety margins to
validate process design codes
-
Assessment of SG
thermal hydraulic instabilities viz. Ledinegg and density wave
instability SG behavior with few tubes plugged.
-
Assessment of
temperature distribution on the sodium side of SG under
different steady state and transient operating conditions to
validate multi dimensional computer codes.
-
Assessment of heat
transfer area margins in the sodium to air cooler similar to the
one used in the decay heat removal system of PFBR.
-
Assessment of
propagation of hydrogen in the sodium circuit in a simulated
sodium water reaction.
-
Assessment of time of
depressurization of SG tube side (water/steam).
-
We have a team of
staff with very good experience in the operation of sodium
system, sodium pumps, sodium instrumentation, oil fired heater
system and high pressure steam water system.
|
|